We bring clear power for the world

A16-30-10 AC Contactor

Short Description:

A16-30-10, Nofuel, direct replacement contactors for ABB A16-30-10, A-Line series,
3 pole, 3 phase, 17Amp, 600 Volt, 5HP @ 240V, 10HP @ 480V, 15HP @ 600V,
installed with 120VAC coil and 1NO aux contact, AC contactor


  • FOB Price: US $5 - 499 / Piece
  • Supply Ability: 5000 Pcs per Month
  • Payment Terms: L/C, D/P, T/T, Paypal
  • Control voltage: 24V 48V 72V 110V 230V 240V 380V 440V 480V
  • Brand : Nofuel
  • Product Detail

    Product Tags

    Maximum UL/CSA horsepower ratings

    • Includes NEMA sizes 00 – 3
    • CE mark
    • Compact space saving design
    • Standard auxiliary contact configurations:
      A9 – A40 1 N.O. or 1 N.C.
      A50 – A110 1 N.O. and 1 N.C.
      Can be supplied without auxiliaries
    • Additional auxiliary contact blocks are available
    • D.C. ratings & D.C. control operation available
    • Fast, snap-on DIN rail mounting
    • Double break contact design
    • Snap-on front mounted accessories

    AC Control supply
    Model No.
    Standard 
    Part Number
    General
    use
    rating
    600 V AC
    AC-3 Rated 
    operational power
    3-phase
    motor
    rating
    NEMA size Weight 
    in kg
    Model Amp  KW@480 HP@480V NEMA size
    A9 A9-30-10 9 4 5 0.4
    A12 A12-30-10 12 5.5 7.5 0 0.4
    A16 A16-30-10 16 7.5 10 0 0.4
    A26 A26-30-10 26 11 20 1 0.6
    A30 A30-30-10 30 15 25 1P 0.8
    A40 A40-30-10 40 18.6 30 1P 0.8
    A50 A50-30-11 50 22 40 2 1.2
    A63 A63-30-11 63 30 60 0 1.2
    A75 A75-30-11 75 37 60 0 1.2
    A95 A95-30-11 95 45 60 0 2.2
    A110 A110-30-11 110 55 75 0 2.2
    A145 A145-30-11 145 75 95 0 2.2
    A185 A185-30-11 185 90 125 0 3.5
    A210 A210-30-11 210 110 150 0 6.1
    A260 A260-30-11 260 140 200 0 6.5
    A300 A300-30-11 300 160 250 0 6.6

     

    A9 A9-30-10, Nofuel, direct replacement contactors for ABB A9-30-10, A-Line series,
    3 pole,3 phase, 9Amp, 600 Volt, 2HP @ 240V, 5HP @ 480V, 7.5HP @ 600V,
    installed with 120VAC coil and 1NO aux contact, AC contactor
    A12 A12-30-10, Nofuel, direct replacement contactors for ABB A12-30-10, A-Line series,
    3 pole, 3 phase, 11Amp, 600 Volt, 3HP @ 240V, 7.5HP @ 480V, 10HP @ 600V,
    installed with 120VAC coil and 1NO aux contact, AC contactor
    A16 A16-30-10, Nofuel, direct replacement contactors for ABB A16-30-10, A-Line series,
    3 pole, 3 phase, 17Amp, 600 Volt, 5HP @ 240V, 10HP @ 480V, 15HP @ 600V,
    installed with 120VAC coil and 1NO aux contact, AC contactor
    A26 A26-30-10, Nofuel, direct replacement contactors for ABB A26-30-10, A-Line series,
    3 pole, 3 phase, 28Amp, 600 Volt, 10HP @ 240V, 20HP @ 480V, 25HP @ 600V,
    installed with 120VAC coil and 1NO aux contact, AC contactor
    A30 A30-30-10, Nofuel, direct replacement contactors for ABB A30-30-10, A-Line series,
    3 pole, 3 phase, 34Amp, 600 Volt, 10HP @ 240V, 25HP @ 480V, 30HP @ 600V,
    installed with 120VAC coil and 1NO aux contact, AC contactor
    A40 A40-30-10, Nofuel, contactors, direct replacement contactors for ABB A40-30-10,
    A-Line series, 3 pole, 3 phase, 42Amp, 600 Volt, 15HP @ 240V, 30HP @ 480V,
    40HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor
    A50 A50-30-11, Nofuel, direct replacement contactors for  ABB A50-30-11, A-Line series,
    3 pole, 3 phase, 54Amp, 600 Volt, 20HP @ 240V, 40HP @ 480V, 50HP @ 600V,
    installed with 120VAC coil and 1NO/1NC aux contact, AC contactor
    A63 A63-30-11, Nofuel, direct replacement contactors for ABB A63-30-11, A-Line series,
    3 pole, 3 phase, 65Amp, 600 Volt, 25HP @ 240V, 50HP @ 480V, 60HP @ 600V,
    installed with 120VAC coil and 1NO/1NC aux contact, AC contactor
    A75 A75-30-11, Nofuel, direct replacement contactors for ABB A75-30-11, A-Line series,
    3 pole, 3 phase, 80Amp, 600 Volt, 30HP @ 240V, 60HP @ 480V, 75HP @ 600V,
    installed with 120VAC coil and 1NO/1NC aux contact, AC contactor
    A95 A95-30-11, Nofuel, direct replacement contactors for ABB A95-30-11, A-Line series,
    3 pole, 3 phase, 95Amp, 600 Volt, 30HP @ 240V, 60HP @ 480V, 75HP @ 600V,
    installed with 120VAC coil and 1NO/1NC aux contact, AC contactor
    A110 A110-30-11, Nofuel, direct replacement contactors for ABB A110-30-11, A-Line series,
    3 pole, 3 phase, 110Amp, 600 Volt, 40HP @ 240V, 75HP @ 480V, 100HP @ 600V,
    installed with 120VAC coil and 1NO/1NC aux contact, AC contactor
    A145 A145-30-11, Nofuel, direct replacement contactors for ABB A145-30-11, A-Line series,
    3 pole, 3 phase, 130Amp, 600 Volt, 50HP @ 240V, 100HP @ 480V, 125HP @ 600V,
    installed with 120VAC coil and 1NO/1NC aux contact, AC contactor
    A185 A185-30-11, Nofuel, direct replacement contactors for ABB A185-30-11, A-Line series,
    3 pole, 3 phase, 156Amp, 600 Volt, 60HP @ 240V, 125HP @ 480V, 150HP @ 600V,
    installed with 120VAC coil and 1NO/1NC aux contact, AC contactor
    A210 A210-30-11, Nofuel, direct replacement contactors for ABB A210-30-11, A-Line series,
    3 pole, 3 phase, 192Amp, 600 Volt, 75HP @ 240V, 150HP @ 480V, 200HP @ 600V,
    installed with 120VAC coil and 1NO/1NC aux contact, AC contactor
    A260 A260-30-11, Nofuel, direct replacement contactors for ABB A260-30-11, A-Line series,
    3 pole, 3 phase, 248Amp, 600 Volt, 100HP @ 240V, 200HP @ 480V, 250HP @ 600V,
    installed with 120VAC coil and 1NO/1NC aux contact, AC contactor
    A300 A300-30-11, Nofuel, direct replacement contactors for ABB A300-30-11, A-Line series,
    3 pole, 3 phase, 302Amp, 600 Volt, 100HP @ 240V, 250HP @ 480V, 300HP @ 600V,
    installed with 120VAC coil and 1NO/1NC aux contact, AC contactor

  • Previous:
  • Next:

  • 
    WhatsApp Online Chat !