Factory directly Forklift Parts 24v 100a Contactor Relays - NB1-63 Three Pole din rail circuit breaker – Simply Buy Detail:
DC MCB1(Mini circuit breaker)supplementary protectors are designed to provide over current protection within appliances or electrical equipment, where a branch circuit protection is already provided or not required. Devices are designed for direct current (DC) control circuit applications.It’s din rail mounted type and Current form 1A to 63A and voltage 110VDC ,125VDC to 250VDC 440V DC .
Features:
• B C trip curves models available for general
use and DC applications
• D trip curve models available for high starting
current applications such as motor starting
• Current ratings up to 63A
• Maximum 480VAC (multi-pole), 277VAC (single-pole)
• 5000 A Interrupt Rating
• DIN rail mount chassis
• Captive terminal screws won’t fall out
• Mechanical life: 20000 times.
• Electric life: 4000 times
• Captive terminal screws won’t fall out
Tripping curves
B curve
When the short-circuit currents are weak (generators, long cables).
Power circuit:
ratings: 1 to 63 A set at 30 °C
tripping curve: the magnetic trip units operate between 3 and 5 In.
C curve
Cables feeding conventional loads.
Power circuit:
ratings: 0.5 to 63 A set at 30 °C
tripping curve: the magnetic trip units operate between 5 and 10 In.
D curve
Loads with high inrush currents (motors, transformers).
Power circuit:
ratings: 0.5 to 63 A set at 40 °C
tripping curve: the magnetic trip units operate between 10 and 14 In.
Max Voltage | Rated Amps | 1 Pole | 2 Pole | 3 Pole | 4 Pole |
B Curve 5KA Single-pole: 277VAC 110VDC Multi-pole: 480VAC 125VDC |
1 | MCB1-B1-1P | MCB1-B1-2P | MCB1-B1-3P | MCB1-B1-4P |
2 | MCB1-B2-1P | MCB1-B2-2P | MCB1-B2-3P | MCB1-B2-4P | |
3 | MCB1-B3-1P | MCB1-B3-2P | MCB1-B3-3P | MCB1-B3-4P | |
4 | MCB1-B4-1P | MCB1-B4-2P | MCB1-B4-3P | MCB1-B4-4P | |
6 | MCB1-B6-1P | MCB1-B6-2P | MCB1-B6-3P | MCB1-B6-4P | |
10 | MCB1-B10-1P | MCB1-B10-2P | MCB1-B10-3P | MCB1-B10-4P | |
16 | MCB1-B16-1P | MCB1-B16-2P | MCB1-B16-3P | MCB1-B16-4P | |
20 | MCB1-B20-1P | MCB1-B20-2P | MCB1-B20-3P | MCB1-B20-4P | |
25 | MCB1-B25-1P | MCB1-B25-2P | MCB1-B25-3P | MCB1-B25-4P | |
32 | MCB1-B32-1P | MCB1-B32-2P | MCB1-B32-3P | MCB1-B32-4P | |
40 | MCB1-B40-1P | MCB1-B40-2P | MCB1-B40-3P | MCB1-B40-4P | |
50 | MCB1-B50-1P | MCB1-B50-2P | MCB1-B50-3P | MCB1-B50-4P | |
63 | MCB1-B63-1P | MCB1-B63-2P | MCB1-B63-3P | MCB1-B63-4P | |
Max Voltage | Rated Amps | 1 Pole | 2 Pole | 3 Pole | 4 Pole |
C Curve 5KA Single-pole: 277VAC 110VDC Multi-pole: 480VAC 125VDC |
1 | MCB1-C1-1P | MCB1-C1-2P | MCB1-C1-3P | MCB1-C1-4P |
2 | MCB1-C2-1P | MCB1-C2-2P | MCB1-C2-3P | MCB1-C2-4P | |
3 | MCB1-C3-1P | MCB1-C3-2P | MCB1-C3-3P | MCB1-C3-4P | |
4 | MCB1-C4-1P | MCB1-C4-2P | MCB1-C4-3P | MCB1-C4-4P | |
6 | MCB1-C6-1P | MCB1-C6-2P | MCB1-C6-3P | MCB1-C6-4P | |
10 | MCB1-C10-1P | MCB1-C10-2P | MCB1-C10-3P | MCB1-C10-4P | |
16 | MCB1-C16-1P | MCB1-C16-2P | MCB1-C16-3P | MCB1-C16-4P | |
20 | MCB1-C20-1P | MCB1-C20-2P | MCB1-C20-3P | MCB1-C20-4P | |
25 | MCB1-C25-1P | MCB1-C25-2P | MCB1-C25-3P | MCB1-C25-4P | |
32 | MCB1-C32-1P | MCB1-C32-2P | MCB1-C32-3P | MCB1-C32-4P | |
40 | MCB1-C40-1P | MCB1-C40-2P | MCB1-C40-3P | MCB1-C40-4P | |
50 | MCB1-C50-1P | MCB1-C50-2P | MCB1-C50-3P | MCB1-C50-4P | |
63 | MCB1-C63-1P | MCB1-C63-2P | MCB1-C63-3P | MCB1-C63-4P | |
Max Voltage | Rated Amps | 1 Pole | 2 Pole | 3 Pole | 4 Pole |
D Curve 5KA Single-pole: 277VAC 110VDC Multi-pole: 480VAC 125VDC |
1 | MCB1-D1-1P | MCB1-D1-2P | MCB1-D1-3P | MCB1-D1-4P |
2 | MCB1-D2-1P | MCB1-D2-2P | MCB1-D2-3P | MCB1-D2-4P | |
3 | MCB1-D3-1P | MCB1-D3-2P | MCB1-D3-3P | MCB1-D3-4P | |
4 | MCB1-D4-1P | MCB1-D4-2P | MCB1-D4-3P | MCB1-D4-4P | |
6 | MCB1-D6-1P | MCB1-D6-2P | MCB1-D6-3P | MCB1-D6-4P | |
10 | MCB1-D10-1P | MCB1-D10-2P | MCB1-D10-3P | MCB1-D10-4P | |
16 | MCB1-D16-1P | MCB1-D16-2P | MCB1-D16-3P | MCB1-D16-4P | |
20 | MCB1-D20-1P | MCB1-D20-2P | MCB1-D20-3P | MCB1-D20-4P | |
25 | MCB1-D25-1P | MCB1-D25-2P | MCB1-D25-3P | MCB1-D25-4P | |
32 | MCB1-D32-1P | MCB1-D32-2P | MCB1-D32-3P | MCB1-D32-4P | |
40 | MCB1-D40-1P | MCB1-D40-2P | MCB1-D40-3P | MCB1-D40-4P | |
50 | MCB1-D50-1P | MCB1-D50-2P | MCB1-D50-3P | MCB1-D50-4P | |
63 | MCB1-D63-1P | MCB1-D63-2P | MCB1-D63-3P | MCB1-D63-4P |
Product detail pictures:
Related Product Guide:
Battlefield V’s creators: female characters are ‘here to stay’ | Lrd12 Overload Relay
Senate committee cancels votes on judicial nominees after Jeff Flake’s Mueller ultimatum | Lrd12 Overload Relay
The very rich projects management experiences and one to one service model make the high importance of business communication and our easy understanding of your expectations for Factory directly Forklift Parts 24v 100a Contactor Relays - NB1-63 Three Pole din rail circuit breaker – Simply Buy, The product will supply to all over the world, such as: South Korea , Suriname , Greek , Each year, many of our customers would visit our company and achieve great business advancements working with us. We sincerely welcome you to visit us at any time and together we will prevail to a greater success in the hair industry.
By Poppy from Ireland - 2015.12.11 11:26
The goods are very perfect and the company sales manager is warmful, we will come to this company to purchase next time.
By Esther from Riyadh - 2015.11.28 16:25