Factory wholesale Contactor With Auxiliary Contacts - A9-30-10 AC Contactor – Simply Buy Detail:
Maximum UL/CSA horsepower ratings
• Includes NEMA sizes 00 – 3
• CE mark
• Compact space saving design
• Standard auxiliary contact configurations:
A9 – A40 1 N.O. or 1 N.C.
A50 – A110 1 N.O. and 1 N.C.
Can be supplied without auxiliaries
• Additional auxiliary contact blocks are available
• D.C. ratings & D.C. control operation available
• Fast, snap-on DIN rail mounting
• Double break contact design
• Snap-on front mounted accessories
AC Control supply Model No. |
Standard Part Number |
General use rating 600 V AC |
AC-3 Rated operational power |
3-phase motor rating |
NEMA size | Weight in kg |
Model | Amp | KW@480 | HP@480V | NEMA size | ||
A9 | A9-30-10 | 9 | 4 | 5 | 0 | 0.4 |
A12 | A12-30-10 | 12 | 5.5 | 7.5 | 0 | 0.4 |
A16 | A16-30-10 | 16 | 7.5 | 10 | 0 | 0.4 |
A26 | A26-30-10 | 26 | 11 | 20 | 1 | 0.6 |
A30 | A30-30-10 | 30 | 15 | 25 | 1P | 0.8 |
A40 | A40-30-10 | 40 | 18.6 | 30 | 1P | 0.8 |
A50 | A50-30-11 | 50 | 22 | 40 | 2 | 1.2 |
A63 | A63-30-11 | 63 | 30 | 60 | 0 | 1.2 |
A75 | A75-30-11 | 75 | 37 | 60 | 0 | 1.2 |
A95 | A95-30-11 | 95 | 45 | 60 | 0 | 2.2 |
A110 | A110-30-11 | 110 | 55 | 75 | 0 | 2.2 |
A145 | A145-30-11 | 145 | 75 | 95 | 0 | 2.2 |
A185 | A185-30-11 | 185 | 90 | 125 | 0 | 3.5 |
A210 | A210-30-11 | 210 | 110 | 150 | 0 | 6.1 |
A260 | A260-30-11 | 260 | 140 | 200 | 0 | 6.5 |
A300 | A300-30-11 | 300 | 160 | 250 | 0 | 6.6 |
A9 | A9-30-10, Nofuel, direct replacement contactors for ABB A9-30-10, A-Line series, 3 pole,3 phase, 9Amp, 600 Volt, 2HP @ 240V, 5HP @ 480V, 7.5HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A12 | A12-30-10, Nofuel, direct replacement contactors for ABB A12-30-10, A-Line series, 3 pole, 3 phase, 11Amp, 600 Volt, 3HP @ 240V, 7.5HP @ 480V, 10HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A16 | A16-30-10, Nofuel, direct replacement contactors for ABB A16-30-10, A-Line series, 3 pole, 3 phase, 17Amp, 600 Volt, 5HP @ 240V, 10HP @ 480V, 15HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A26 | A26-30-10, Nofuel, direct replacement contactors for ABB A26-30-10, A-Line series, 3 pole, 3 phase, 28Amp, 600 Volt, 10HP @ 240V, 20HP @ 480V, 25HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A30 | A30-30-10, Nofuel, direct replacement contactors for ABB A30-30-10, A-Line series, 3 pole, 3 phase, 34Amp, 600 Volt, 10HP @ 240V, 25HP @ 480V, 30HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A40 | A40-30-10, Nofuel, contactors, direct replacement contactors for ABB A40-30-10, A-Line series, 3 pole, 3 phase, 42Amp, 600 Volt, 15HP @ 240V, 30HP @ 480V, 40HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A50 | A50-30-11, Nofuel, direct replacement contactors for ABB A50-30-11, A-Line series, 3 pole, 3 phase, 54Amp, 600 Volt, 20HP @ 240V, 40HP @ 480V, 50HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A63 | A63-30-11, Nofuel, direct replacement contactors for ABB A63-30-11, A-Line series, 3 pole, 3 phase, 65Amp, 600 Volt, 25HP @ 240V, 50HP @ 480V, 60HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A75 | A75-30-11, Nofuel, direct replacement contactors for ABB A75-30-11, A-Line series, 3 pole, 3 phase, 80Amp, 600 Volt, 30HP @ 240V, 60HP @ 480V, 75HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A95 | A95-30-11, Nofuel, direct replacement contactors for ABB A95-30-11, A-Line series, 3 pole, 3 phase, 95Amp, 600 Volt, 30HP @ 240V, 60HP @ 480V, 75HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A110 | A110-30-11, Nofuel, direct replacement contactors for ABB A110-30-11, A-Line series, 3 pole, 3 phase, 110Amp, 600 Volt, 40HP @ 240V, 75HP @ 480V, 100HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A145 | A145-30-11, Nofuel, direct replacement contactors for ABB A145-30-11, A-Line series, 3 pole, 3 phase, 130Amp, 600 Volt, 50HP @ 240V, 100HP @ 480V, 125HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A185 | A185-30-11, Nofuel, direct replacement contactors for ABB A185-30-11, A-Line series, 3 pole, 3 phase, 156Amp, 600 Volt, 60HP @ 240V, 125HP @ 480V, 150HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A210 | A210-30-11, Nofuel, direct replacement contactors for ABB A210-30-11, A-Line series, 3 pole, 3 phase, 192Amp, 600 Volt, 75HP @ 240V, 150HP @ 480V, 200HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A260 | A260-30-11, Nofuel, direct replacement contactors for ABB A260-30-11, A-Line series, 3 pole, 3 phase, 248Amp, 600 Volt, 100HP @ 240V, 200HP @ 480V, 250HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A300 | A300-30-11, Nofuel, direct replacement contactors for ABB A300-30-11, A-Line series, 3 pole, 3 phase, 302Amp, 600 Volt, 100HP @ 240V, 250HP @ 480V, 300HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
Product detail pictures:

















Related Product Guide:
Ameriprise Finl Com (AMP) Shareholder Fdx Advisors Has Increased Stake by $342,804; Fukoku Mutual Life Insurance Company Stake in Amazon Com (AMZN) Raised as Share Price Declined | Circuit Breaker Parts
The Walking Dead developer Telltale hit with devastating layoffs as part of a ‘majority studio closure’ | 25 Amp Circuit Breaker
go on to boost, to be certain item quality in line with market and buyer standard demands. Our firm has a excellent assurance procedure happen to be established for Factory wholesale Contactor With Auxiliary Contacts - A9-30-10 AC Contactor – Simply Buy, The product will supply to all over the world, such as: Algeria , Liverpool , Bolivia , Since the establishment of our company, we've realized the importance of providing good quality goods and the best before-sales and after-sales services. Most problems between global suppliers and clients are due to poor communication. Culturally, suppliers can be reluctant to question points they do not understand. We break down these barriers to ensure you get what you want to the level you expect, when you want it.

The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.