We bring clear power for the world

Good Quality Starter Motor For Peugeot 405 - A line contactor – Simply Buy

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our organization promises all customers with the first-class products and solutions and the most satisfying post-sale service. We warmly welcome our regular and new clients to join us for Circuit Breaker Company , 3tf Motor Contactor Coil , Main Contact Zl95 , Safety through innovation is our promise to each other.
Good Quality Starter Motor For Peugeot 405 - A line contactor – Simply Buy Detail:

Detailed Description:

Mainly used for controlling 3-phase motors and power circuits up to 690 V AC or

220 V DC. These contactors are of the block type design with 3 main poles and 1 built-in auxiliary contact .

Directly replacement ABB A-Line Contactor with NEMA, UL, IEC, CSA, VDE standards

A9 A9-30-10, Nofuel, direct replacement contactors for ABB A9-30-10, A-Line series,
3 pole,3 phase, 9Amp, 600 Volt, 2HP @ 240V, 5HP @ 480V, 7.5HP @ 600V,
installed with 120VAC coil and 1NO aux contact, AC contactor
A12 A12-30-10, Nofuel, direct replacement contactors for ABB A12-30-10, A-Line series,
3 pole, 3 phase, 11Amp, 600 Volt, 3HP @ 240V, 7.5HP @ 480V, 10HP @ 600V,
installed with 120VAC coil and 1NO aux contact, AC contactor
A16 A16-30-10, Nofuel, direct replacement contactors for ABB A16-30-10, A-Line series,
3 pole, 3 phase, 17Amp, 600 Volt, 5HP @ 240V, 10HP @ 480V, 15HP @ 600V,
installed with 120VAC coil and 1NO aux contact, AC contactor
A26 A26-30-10, Nofuel, direct replacement contactors for ABB A26-30-10, A-Line series,
3 pole, 3 phase, 28Amp, 600 Volt, 10HP @ 240V, 20HP @ 480V, 25HP @ 600V,
installed with 120VAC coil and 1NO aux contact, AC contactor
A30 A30-30-10, Nofuel, direct replacement contactors for ABB A30-30-10, A-Line series,
3 pole, 3 phase, 34Amp, 600 Volt, 10HP @ 240V, 25HP @ 480V, 30HP @ 600V,
installed with 120VAC coil and 1NO aux contact, AC contactor
A40 A40-30-10, Nofuel, contactors, direct replacement contactors for ABB A40-30-10,
A-Line series, 3 pole, 3 phase, 42Amp, 600 Volt, 15HP @ 240V, 30HP @ 480V,
40HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor
A50 A50-30-11, Nofuel, direct replacement contactors for  ABB A50-30-11, A-Line series,
3 pole, 3 phase, 54Amp, 600 Volt, 20HP @ 240V, 40HP @ 480V, 50HP @ 600V,
installed with 120VAC coil and 1NO/1NC aux contact, AC contactor
A63 A63-30-11, Nofuel, direct replacement contactors for ABB A63-30-11, A-Line series,
3 pole, 3 phase, 65Amp, 600 Volt, 25HP @ 240V, 50HP @ 480V, 60HP @ 600V,
installed with 120VAC coil and 1NO/1NC aux contact, AC contactor
A75 A75-30-11, Nofuel, direct replacement contactors for ABB A75-30-11, A-Line series,
3 pole, 3 phase, 80Amp, 600 Volt, 30HP @ 240V, 60HP @ 480V, 75HP @ 600V,
installed with 120VAC coil and 1NO/1NC aux contact, AC contactor
A95 A95-30-11, Nofuel, direct replacement contactors for ABB A95-30-11, A-Line series,
3 pole, 3 phase, 95Amp, 600 Volt, 30HP @ 240V, 60HP @ 480V, 75HP @ 600V,
installed with 120VAC coil and 1NO/1NC aux contact, AC contactor
A110 A110-30-11, Nofuel, direct replacement contactors for ABB A110-30-11, A-Line series,
3 pole, 3 phase, 110Amp, 600 Volt, 40HP @ 240V, 75HP @ 480V, 100HP @ 600V,
installed with 120VAC coil and 1NO/1NC aux contact, AC contactor
A145 A145-30-11, Nofuel, direct replacement contactors for ABB A145-30-11, A-Line series,
3 pole, 3 phase, 130Amp, 600 Volt, 50HP @ 240V, 100HP @ 480V, 125HP @ 600V,
installed with 120VAC coil and 1NO/1NC aux contact, AC contactor
A185 A185-30-11, Nofuel, direct replacement contactors for ABB A185-30-11, A-Line series,
3 pole, 3 phase, 156Amp, 600 Volt, 60HP @ 240V, 125HP @ 480V, 150HP @ 600V,
installed with 120VAC coil and 1NO/1NC aux contact, AC contactor
A210 A210-30-11, Nofuel, direct replacement contactors for ABB A210-30-11, A-Line series,
3 pole, 3 phase, 192Amp, 600 Volt, 75HP @ 240V, 150HP @ 480V, 200HP @ 600V,
installed with 120VAC coil and 1NO/1NC aux contact, AC contactor
A260 A260-30-11, Nofuel, direct replacement contactors for ABB A260-30-11, A-Line series,
3 pole, 3 phase, 248Amp, 600 Volt, 100HP @ 240V, 200HP @ 480V, 250HP @ 600V,
installed with 120VAC coil and 1NO/1NC aux contact, AC contactor
A300 A300-30-11, Nofuel, direct replacement contactors for ABB A300-30-11, A-Line series,
3 pole, 3 phase, 302Amp, 600 Volt, 100HP @ 240V, 250HP @ 480V, 300HP @ 600V,
installed with 120VAC coil and 1NO/1NC aux contact, AC contactor

 

AC Control supply
Model No.
Standard 
Part Number
General
use
rating
600 V AC
AC-3 Rated 
operational power
3-phase
motor
rating
NEMA size Weight 
in kg
Model Amp  KW@480 HP@480V NEMA size
A9 A9-30-10 9 4 5 0.4
A12 A12-30-10 12 5.5 7.5 0 0.4
A16 A16-30-10 16 7.5 10 0 0.4
A26 A26-30-10 26 11 20 1 0.6
A30 A30-30-10 30 15 25 1P 0.8
A40 A40-30-10 40 18.6 30 1P 0.8
A50 A50-30-11 50 22 40 2 1.2
A63 A63-30-11 63 30 60 0 1.2
A75 A75-30-11 75 37 60 0 1.2
A95 A95-30-11 95 45 60 0 2.2
A110 A110-30-11 110 55 75 0 2.2
A145 A145-30-11 145 75 95 0 2.2
A185 A185-30-11 185 90 125 0 3.5
A210 A210-30-11 210 110 150 0 6.1
A260 A260-30-11 260 140 200 0 6.5
A300 A300-30-11 300 160 250 0 6.6

 


Product detail pictures:

Good Quality Starter Motor For Peugeot 405 -
 A line contactor – Simply Buy detail pictures

Good Quality Starter Motor For Peugeot 405 -
 A line contactor – Simply Buy detail pictures

Good Quality Starter Motor For Peugeot 405 -
 A line contactor – Simply Buy detail pictures

Good Quality Starter Motor For Peugeot 405 -
 A line contactor – Simply Buy detail pictures

Good Quality Starter Motor For Peugeot 405 -
 A line contactor – Simply Buy detail pictures

Good Quality Starter Motor For Peugeot 405 -
 A line contactor – Simply Buy detail pictures

Good Quality Starter Motor For Peugeot 405 -
 A line contactor – Simply Buy detail pictures

Good Quality Starter Motor For Peugeot 405 -
 A line contactor – Simply Buy detail pictures

Good Quality Starter Motor For Peugeot 405 -
 A line contactor – Simply Buy detail pictures

Good Quality Starter Motor For Peugeot 405 -
 A line contactor – Simply Buy detail pictures

Good Quality Starter Motor For Peugeot 405 -
 A line contactor – Simply Buy detail pictures

Good Quality Starter Motor For Peugeot 405 -
 A line contactor – Simply Buy detail pictures

Good Quality Starter Motor For Peugeot 405 -
 A line contactor – Simply Buy detail pictures

Good Quality Starter Motor For Peugeot 405 -
 A line contactor – Simply Buy detail pictures

Good Quality Starter Motor For Peugeot 405 -
 A line contactor – Simply Buy detail pictures

Good Quality Starter Motor For Peugeot 405 -
 A line contactor – Simply Buy detail pictures

Good Quality Starter Motor For Peugeot 405 -
 A line contactor – Simply Buy detail pictures


Related Product Guide:
What to Consider When Buying and Installing a Home Electric Vehicle Charging Station | 25 Amp Circuit Breaker
New Google Classroom update makes it harder to cheat on quizzes | Circuit Breaker Parts

We are going to make every single effort for being excellent and excellent, and accelerate our ways for standing while in the rank of international top-grade and high-tech enterprises for Good Quality Starter Motor For Peugeot 405 - A line contactor – Simply Buy, The product will supply to all over the world, such as: Istanbul , Marseille , Dubai , It is our customers' satisfaction over our products and services that always inspires us to do better in this business. We build mutually beneficial relationship with our clients by giving them large selection of premium car parts at marked down prices. We offer wholesale prices on all our quality parts so you are guaranteed greater savings.
  • This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.
    5 Stars By Lee from Detroit - 2015.07.27 12:26
    The quality of the products is very good, especially in the details, can be seen that the company work actively to satisfy customer's interest, a nice supplier.
    5 Stars By Gwendolyn from Kyrgyzstan - 2016.01.11 17:15
    
    WhatsApp Online Chat !