OEM Factory for 2.5a For Lci-d Ac Contactor – Thermal Relay - A16-30-10 AC Contactor – Simply Buy Detail:
Maximum UL/CSA horsepower ratings
• Includes NEMA sizes 00 – 3
• CE mark
• Compact space saving design
• Standard auxiliary contact configurations:
A9 – A40 1 N.O. or 1 N.C.
A50 – A110 1 N.O. and 1 N.C.
Can be supplied without auxiliaries
• Additional auxiliary contact blocks are available
• D.C. ratings & D.C. control operation available
• Fast, snap-on DIN rail mounting
• Double break contact design
• Snap-on front mounted accessories
AC Control supply Model No. |
Standard Part Number |
General use rating 600 V AC |
AC-3 Rated operational power |
3-phase motor rating |
NEMA size | Weight in kg |
Model | Amp | KW@480 | HP@480V | NEMA size | ||
A9 | A9-30-10 | 9 | 4 | 5 | 0 | 0.4 |
A12 | A12-30-10 | 12 | 5.5 | 7.5 | 0 | 0.4 |
A16 | A16-30-10 | 16 | 7.5 | 10 | 0 | 0.4 |
A26 | A26-30-10 | 26 | 11 | 20 | 1 | 0.6 |
A30 | A30-30-10 | 30 | 15 | 25 | 1P | 0.8 |
A40 | A40-30-10 | 40 | 18.6 | 30 | 1P | 0.8 |
A50 | A50-30-11 | 50 | 22 | 40 | 2 | 1.2 |
A63 | A63-30-11 | 63 | 30 | 60 | 0 | 1.2 |
A75 | A75-30-11 | 75 | 37 | 60 | 0 | 1.2 |
A95 | A95-30-11 | 95 | 45 | 60 | 0 | 2.2 |
A110 | A110-30-11 | 110 | 55 | 75 | 0 | 2.2 |
A145 | A145-30-11 | 145 | 75 | 95 | 0 | 2.2 |
A185 | A185-30-11 | 185 | 90 | 125 | 0 | 3.5 |
A210 | A210-30-11 | 210 | 110 | 150 | 0 | 6.1 |
A260 | A260-30-11 | 260 | 140 | 200 | 0 | 6.5 |
A300 | A300-30-11 | 300 | 160 | 250 | 0 | 6.6 |
A9 | A9-30-10, Nofuel, direct replacement contactors for ABB A9-30-10, A-Line series, 3 pole,3 phase, 9Amp, 600 Volt, 2HP @ 240V, 5HP @ 480V, 7.5HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A12 | A12-30-10, Nofuel, direct replacement contactors for ABB A12-30-10, A-Line series, 3 pole, 3 phase, 11Amp, 600 Volt, 3HP @ 240V, 7.5HP @ 480V, 10HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A16 | A16-30-10, Nofuel, direct replacement contactors for ABB A16-30-10, A-Line series, 3 pole, 3 phase, 17Amp, 600 Volt, 5HP @ 240V, 10HP @ 480V, 15HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A26 | A26-30-10, Nofuel, direct replacement contactors for ABB A26-30-10, A-Line series, 3 pole, 3 phase, 28Amp, 600 Volt, 10HP @ 240V, 20HP @ 480V, 25HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A30 | A30-30-10, Nofuel, direct replacement contactors for ABB A30-30-10, A-Line series, 3 pole, 3 phase, 34Amp, 600 Volt, 10HP @ 240V, 25HP @ 480V, 30HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A40 | A40-30-10, Nofuel, contactors, direct replacement contactors for ABB A40-30-10, A-Line series, 3 pole, 3 phase, 42Amp, 600 Volt, 15HP @ 240V, 30HP @ 480V, 40HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A50 | A50-30-11, Nofuel, direct replacement contactors for ABB A50-30-11, A-Line series, 3 pole, 3 phase, 54Amp, 600 Volt, 20HP @ 240V, 40HP @ 480V, 50HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A63 | A63-30-11, Nofuel, direct replacement contactors for ABB A63-30-11, A-Line series, 3 pole, 3 phase, 65Amp, 600 Volt, 25HP @ 240V, 50HP @ 480V, 60HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A75 | A75-30-11, Nofuel, direct replacement contactors for ABB A75-30-11, A-Line series, 3 pole, 3 phase, 80Amp, 600 Volt, 30HP @ 240V, 60HP @ 480V, 75HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A95 | A95-30-11, Nofuel, direct replacement contactors for ABB A95-30-11, A-Line series, 3 pole, 3 phase, 95Amp, 600 Volt, 30HP @ 240V, 60HP @ 480V, 75HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A110 | A110-30-11, Nofuel, direct replacement contactors for ABB A110-30-11, A-Line series, 3 pole, 3 phase, 110Amp, 600 Volt, 40HP @ 240V, 75HP @ 480V, 100HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A145 | A145-30-11, Nofuel, direct replacement contactors for ABB A145-30-11, A-Line series, 3 pole, 3 phase, 130Amp, 600 Volt, 50HP @ 240V, 100HP @ 480V, 125HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A185 | A185-30-11, Nofuel, direct replacement contactors for ABB A185-30-11, A-Line series, 3 pole, 3 phase, 156Amp, 600 Volt, 60HP @ 240V, 125HP @ 480V, 150HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A210 | A210-30-11, Nofuel, direct replacement contactors for ABB A210-30-11, A-Line series, 3 pole, 3 phase, 192Amp, 600 Volt, 75HP @ 240V, 150HP @ 480V, 200HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A260 | A260-30-11, Nofuel, direct replacement contactors for ABB A260-30-11, A-Line series, 3 pole, 3 phase, 248Amp, 600 Volt, 100HP @ 240V, 200HP @ 480V, 250HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A300 | A300-30-11, Nofuel, direct replacement contactors for ABB A300-30-11, A-Line series, 3 pole, 3 phase, 302Amp, 600 Volt, 100HP @ 240V, 250HP @ 480V, 300HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
Product detail pictures:

















Related Product Guide:
Heavy Lift Electromagnet from Microwave Oven Transformers | 19mm Momentary Push Button
Firefox Monitor will let you know if your data has been stolen | Circuit Breaker Parts
We have quite a few great team customers very good at internet marketing, QC, and dealing with kinds of troublesome trouble while in the output approach for OEM Factory for 2.5a For Lci-d Ac Contactor – Thermal Relay - A16-30-10 AC Contactor – Simply Buy, The product will supply to all over the world, such as: Seychelles , Angola , Cape Town , Due to our strict pursues in quality, and after-sale service, our product gets more and more popular around the world. Many clients came to visit our factory and place orders. And there are also many foreign friends who came for sight seeing, or entrust us to buy other stuff for them. You are most welcome to come to China, to our city and to our factory!

The accounts manager made a detailed introduction about the product, so that we have a comprehensive understanding of the product, and ultimately we decided to cooperate.