Online Exporter Lrd22 Overload Relay - NB1-63 Four Pole din rail circuit breaker – Simply Buy Detail:
DC MCB1(Mini circuit breaker)supplementary protectors are designed to provide over current protection within appliances or electrical equipment, where a branch circuit protection is already provided or not required. Devices are designed for direct current (DC) control circuit applications.It’s din rail mounted type and Current form 1A to 63A and voltage 110VDC ,125VDC to 250VDC 440V DC .
Features:
• B C trip curves models available for general
use and DC applications
• D trip curve models available for high starting
current applications such as motor starting
• Current ratings up to 63A
• Maximum 480VAC (multi-pole), 277VAC (single-pole)
• 5000 A Interrupt Rating
• DIN rail mount chassis
• Captive terminal screws won’t fall out
• Mechanical life: 20000 times.
• Electric life: 4000 times
• Captive terminal screws won’t fall out
Tripping curves
B curve
When the short-circuit currents are weak (generators, long cables).
Power circuit:
ratings: 1 to 63 A set at 30 °C
tripping curve: the magnetic trip units operate between 3 and 5 In.
C curve
Cables feeding conventional loads.
Power circuit:
ratings: 0.5 to 63 A set at 30 °C
tripping curve: the magnetic trip units operate between 5 and 10 In.
D curve
Loads with high inrush currents (motors, transformers).
Power circuit:
ratings: 0.5 to 63 A set at 40 °C
tripping curve: the magnetic trip units operate between 10 and 14 In.
Max Voltage | Rated Amps | 1 Pole | 2 Pole | 3 Pole | 4 Pole |
B Curve 5KA Single-pole: 277VAC 110VDC Multi-pole: 480VAC 125VDC |
1 | MCB1-B1-1P | MCB1-B1-2P | MCB1-B1-3P | MCB1-B1-4P |
2 | MCB1-B2-1P | MCB1-B2-2P | MCB1-B2-3P | MCB1-B2-4P | |
3 | MCB1-B3-1P | MCB1-B3-2P | MCB1-B3-3P | MCB1-B3-4P | |
4 | MCB1-B4-1P | MCB1-B4-2P | MCB1-B4-3P | MCB1-B4-4P | |
6 | MCB1-B6-1P | MCB1-B6-2P | MCB1-B6-3P | MCB1-B6-4P | |
10 | MCB1-B10-1P | MCB1-B10-2P | MCB1-B10-3P | MCB1-B10-4P | |
16 | MCB1-B16-1P | MCB1-B16-2P | MCB1-B16-3P | MCB1-B16-4P | |
20 | MCB1-B20-1P | MCB1-B20-2P | MCB1-B20-3P | MCB1-B20-4P | |
25 | MCB1-B25-1P | MCB1-B25-2P | MCB1-B25-3P | MCB1-B25-4P | |
32 | MCB1-B32-1P | MCB1-B32-2P | MCB1-B32-3P | MCB1-B32-4P | |
40 | MCB1-B40-1P | MCB1-B40-2P | MCB1-B40-3P | MCB1-B40-4P | |
50 | MCB1-B50-1P | MCB1-B50-2P | MCB1-B50-3P | MCB1-B50-4P | |
63 | MCB1-B63-1P | MCB1-B63-2P | MCB1-B63-3P | MCB1-B63-4P | |
Max Voltage | Rated Amps | 1 Pole | 2 Pole | 3 Pole | 4 Pole |
C Curve 5KA Single-pole: 277VAC 110VDC Multi-pole: 480VAC 125VDC |
1 | MCB1-C1-1P | MCB1-C1-2P | MCB1-C1-3P | MCB1-C1-4P |
2 | MCB1-C2-1P | MCB1-C2-2P | MCB1-C2-3P | MCB1-C2-4P | |
3 | MCB1-C3-1P | MCB1-C3-2P | MCB1-C3-3P | MCB1-C3-4P | |
4 | MCB1-C4-1P | MCB1-C4-2P | MCB1-C4-3P | MCB1-C4-4P | |
6 | MCB1-C6-1P | MCB1-C6-2P | MCB1-C6-3P | MCB1-C6-4P | |
10 | MCB1-C10-1P | MCB1-C10-2P | MCB1-C10-3P | MCB1-C10-4P | |
16 | MCB1-C16-1P | MCB1-C16-2P | MCB1-C16-3P | MCB1-C16-4P | |
20 | MCB1-C20-1P | MCB1-C20-2P | MCB1-C20-3P | MCB1-C20-4P | |
25 | MCB1-C25-1P | MCB1-C25-2P | MCB1-C25-3P | MCB1-C25-4P | |
32 | MCB1-C32-1P | MCB1-C32-2P | MCB1-C32-3P | MCB1-C32-4P | |
40 | MCB1-C40-1P | MCB1-C40-2P | MCB1-C40-3P | MCB1-C40-4P | |
50 | MCB1-C50-1P | MCB1-C50-2P | MCB1-C50-3P | MCB1-C50-4P | |
63 | MCB1-C63-1P | MCB1-C63-2P | MCB1-C63-3P | MCB1-C63-4P | |
Max Voltage | Rated Amps | 1 Pole | 2 Pole | 3 Pole | 4 Pole |
D Curve 5KA Single-pole: 277VAC 110VDC Multi-pole: 480VAC 125VDC |
1 | MCB1-D1-1P | MCB1-D1-2P | MCB1-D1-3P | MCB1-D1-4P |
2 | MCB1-D2-1P | MCB1-D2-2P | MCB1-D2-3P | MCB1-D2-4P | |
3 | MCB1-D3-1P | MCB1-D3-2P | MCB1-D3-3P | MCB1-D3-4P | |
4 | MCB1-D4-1P | MCB1-D4-2P | MCB1-D4-3P | MCB1-D4-4P | |
6 | MCB1-D6-1P | MCB1-D6-2P | MCB1-D6-3P | MCB1-D6-4P | |
10 | MCB1-D10-1P | MCB1-D10-2P | MCB1-D10-3P | MCB1-D10-4P | |
16 | MCB1-D16-1P | MCB1-D16-2P | MCB1-D16-3P | MCB1-D16-4P | |
20 | MCB1-D20-1P | MCB1-D20-2P | MCB1-D20-3P | MCB1-D20-4P | |
25 | MCB1-D25-1P | MCB1-D25-2P | MCB1-D25-3P | MCB1-D25-4P | |
32 | MCB1-D32-1P | MCB1-D32-2P | MCB1-D32-3P | MCB1-D32-4P | |
40 | MCB1-D40-1P | MCB1-D40-2P | MCB1-D40-3P | MCB1-D40-4P | |
50 | MCB1-D50-1P | MCB1-D50-2P | MCB1-D50-3P | MCB1-D50-4P | |
63 | MCB1-D63-1P | MCB1-D63-2P | MCB1-D63-3P | MCB1-D63-4P |
Product detail pictures:





Related Product Guide:
Tom Baker is turning his long-lost Doctor Who movie script into a novel | 220v Contactor Relay
The Walking Dead developer Telltale hit with devastating layoffs as part of a ‘majority studio closure’ | 25 Amp Circuit Breaker
It can be our duty to satisfy your preferences and successfully serve you. Your pleasure is our best reward. We have been looking forward to the go to for joint expansion for Online Exporter Lrd22 Overload Relay - NB1-63 Four Pole din rail circuit breaker – Simply Buy, The product will supply to all over the world, such as: Colombia , Kenya , Kenya , Besides there are also experienced production and management , advanced production equipment to assure our quality and delivery time , our company pursues the principle of good faith, high-quality and high-efficiency. We guarantee that our company will try our best to reduce customer purchase cost, shorten the period of purchase, stable solutions quality, increase customers' satisfaction and achieve win-win situation .

The sales manager has a good English level and skilled professional knowledge, we have a good communication. He is a warm and cheerful man, we have a pleasant cooperation and we became very good friends in private.

-
Renewable Design for Industrial Relays - NB1 M...
-
Quality Inspection for Reversing Ac Contactor -...
-
Popular Design for 24v Dc Reversing Contactor -...
-
factory Outlets for Ac Magnet Contactor - Load...
-
professional factory for Shunt Trip Mx - Motor...
-
Cheap PriceList for Contactors Lc1-d32 - Compa...