Renewable Design for 3 Phase Electrical Contactor - A line contactor – Simply Buy Detail:
Detailed Description:
Mainly used for controlling 3-phase motors and power circuits up to 690 V AC or
220 V DC. These contactors are of the block type design with 3 main poles and 1 built-in auxiliary contact .
Directly replacement ABB A-Line Contactor with NEMA, UL, IEC, CSA, VDE standards
A9 | A9-30-10, Nofuel, direct replacement contactors for ABB A9-30-10, A-Line series, 3 pole,3 phase, 9Amp, 600 Volt, 2HP @ 240V, 5HP @ 480V, 7.5HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A12 | A12-30-10, Nofuel, direct replacement contactors for ABB A12-30-10, A-Line series, 3 pole, 3 phase, 11Amp, 600 Volt, 3HP @ 240V, 7.5HP @ 480V, 10HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A16 | A16-30-10, Nofuel, direct replacement contactors for ABB A16-30-10, A-Line series, 3 pole, 3 phase, 17Amp, 600 Volt, 5HP @ 240V, 10HP @ 480V, 15HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A26 | A26-30-10, Nofuel, direct replacement contactors for ABB A26-30-10, A-Line series, 3 pole, 3 phase, 28Amp, 600 Volt, 10HP @ 240V, 20HP @ 480V, 25HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A30 | A30-30-10, Nofuel, direct replacement contactors for ABB A30-30-10, A-Line series, 3 pole, 3 phase, 34Amp, 600 Volt, 10HP @ 240V, 25HP @ 480V, 30HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A40 | A40-30-10, Nofuel, contactors, direct replacement contactors for ABB A40-30-10, A-Line series, 3 pole, 3 phase, 42Amp, 600 Volt, 15HP @ 240V, 30HP @ 480V, 40HP @ 600V, installed with 120VAC coil and 1NO aux contact, AC contactor |
A50 | A50-30-11, Nofuel, direct replacement contactors for ABB A50-30-11, A-Line series, 3 pole, 3 phase, 54Amp, 600 Volt, 20HP @ 240V, 40HP @ 480V, 50HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A63 | A63-30-11, Nofuel, direct replacement contactors for ABB A63-30-11, A-Line series, 3 pole, 3 phase, 65Amp, 600 Volt, 25HP @ 240V, 50HP @ 480V, 60HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A75 | A75-30-11, Nofuel, direct replacement contactors for ABB A75-30-11, A-Line series, 3 pole, 3 phase, 80Amp, 600 Volt, 30HP @ 240V, 60HP @ 480V, 75HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A95 | A95-30-11, Nofuel, direct replacement contactors for ABB A95-30-11, A-Line series, 3 pole, 3 phase, 95Amp, 600 Volt, 30HP @ 240V, 60HP @ 480V, 75HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A110 | A110-30-11, Nofuel, direct replacement contactors for ABB A110-30-11, A-Line series, 3 pole, 3 phase, 110Amp, 600 Volt, 40HP @ 240V, 75HP @ 480V, 100HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A145 | A145-30-11, Nofuel, direct replacement contactors for ABB A145-30-11, A-Line series, 3 pole, 3 phase, 130Amp, 600 Volt, 50HP @ 240V, 100HP @ 480V, 125HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A185 | A185-30-11, Nofuel, direct replacement contactors for ABB A185-30-11, A-Line series, 3 pole, 3 phase, 156Amp, 600 Volt, 60HP @ 240V, 125HP @ 480V, 150HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A210 | A210-30-11, Nofuel, direct replacement contactors for ABB A210-30-11, A-Line series, 3 pole, 3 phase, 192Amp, 600 Volt, 75HP @ 240V, 150HP @ 480V, 200HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A260 | A260-30-11, Nofuel, direct replacement contactors for ABB A260-30-11, A-Line series, 3 pole, 3 phase, 248Amp, 600 Volt, 100HP @ 240V, 200HP @ 480V, 250HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
A300 | A300-30-11, Nofuel, direct replacement contactors for ABB A300-30-11, A-Line series, 3 pole, 3 phase, 302Amp, 600 Volt, 100HP @ 240V, 250HP @ 480V, 300HP @ 600V, installed with 120VAC coil and 1NO/1NC aux contact, AC contactor |
AC Control supply Model No. |
Standard Part Number |
General use rating 600 V AC |
AC-3 Rated operational power |
3-phase motor rating |
NEMA size | Weight in kg |
Model | Amp | KW@480 | HP@480V | NEMA size | ||
A9 | A9-30-10 | 9 | 4 | 5 | 0 | 0.4 |
A12 | A12-30-10 | 12 | 5.5 | 7.5 | 0 | 0.4 |
A16 | A16-30-10 | 16 | 7.5 | 10 | 0 | 0.4 |
A26 | A26-30-10 | 26 | 11 | 20 | 1 | 0.6 |
A30 | A30-30-10 | 30 | 15 | 25 | 1P | 0.8 |
A40 | A40-30-10 | 40 | 18.6 | 30 | 1P | 0.8 |
A50 | A50-30-11 | 50 | 22 | 40 | 2 | 1.2 |
A63 | A63-30-11 | 63 | 30 | 60 | 0 | 1.2 |
A75 | A75-30-11 | 75 | 37 | 60 | 0 | 1.2 |
A95 | A95-30-11 | 95 | 45 | 60 | 0 | 2.2 |
A110 | A110-30-11 | 110 | 55 | 75 | 0 | 2.2 |
A145 | A145-30-11 | 145 | 75 | 95 | 0 | 2.2 |
A185 | A185-30-11 | 185 | 90 | 125 | 0 | 3.5 |
A210 | A210-30-11 | 210 | 110 | 150 | 0 | 6.1 |
A260 | A260-30-11 | 260 | 140 | 200 | 0 | 6.5 |
A300 | A300-30-11 | 300 | 160 | 250 | 0 | 6.6 |
Product detail pictures:
Related Product Guide:
Google reportedly paid Andy Rubin $90 million after he allegedly coerced sex from employee | 220v Contactor Relay
This robot uses AI to find Waldo, thereby ruining Where’s Waldo | Lrd12 Overload Relay
The organization keeps for the procedure concept "scientific administration, superior quality and effectiveness primacy, shopper supreme for Renewable Design for 3 Phase Electrical Contactor - A line contactor – Simply Buy, The product will supply to all over the world, such as: Sydney , Belize , Malta , We will supply much better products with diversified designs and professional services. We sincerely welcome friends from over the world to visit our company and cooperate with us on the basis of long-term and mutual benefits.
By Clara from Sweden - 2015.06.28 19:27
The sales person is professional and responsible, warm and polite, we had a pleasant conversation and no language barriers on communication.
By Edward from Canada - 2016.11.01 17:04